Paper 16.045

H. A.M. Daanen et al., "Changes in the Volume and Circumference of the Torso, Leg and Arm after Cycling in the Heat Determined Using 3D Whole Body Scanners", in Proc. of 7th Int. Conf. on 3D Body Scanning Technologies, Lugano, Switzerland, 2016, pp. 45-53, https://doi.org/10.15221/16.045.

Title:

Changes in the Volume and Circumference of the Torso, Leg and Arm
after Cycling in the Heat Determined Using 3D Whole Body Scanners

Authors:

Hein A.M. DAANEN 1,2,3, Koen LEVELS 1, Lisette VONK 2,
Wesley BOSMAN 1, Yorick SCHNEPPER 1, Frank B. TER HAAR 3

1 Department of Human Movement Sciences, Faculty of Behaviour and Movement Sciences, Vrije Universiteit Amsterdam, MOVE Research Institute Amsterdam, The Netherlands;
2 AMFI - Amsterdam Fashion Institute, Amsterdam, The Netherlands;
3 TNO, The Netherlands

Abstract:

Whole body volume changes due to sweat loss after exercise in the heat are well documented, but little is known about the relative contribution of the torso and extremities to these volume changes. It is the purpose of this study to quantify these effects. Therefore, seven healthy male subjects were scanned using a SizeStream and Vitronic whole body scanner prior to and shortly after they lost 1.7 ± 0.1% of their body weight due to cycling at 2 W/kg in a 35°C, 20% relative humidity climatic chamber for 75 minutes. Whole body volume loss was 1.0 ± 0.7% using the SizeStream scanner and 1.3 ± 0.6% using the Vitronic scanner.
Torso volume decreased most with 2.1 ± 1.5% (p=0.009) and 5.6 ± 3.1% (p=0.002) followed by the legs with 1.1 ± 2.7% (N.S.) and 2.9 ± 1.0% (p<0.0001) for SizeStream and Vitronic respectively. Changes in arm volume were negligible. The circumference decreased significantly for the chest and upper legs but not for the waist and arms. We conclude that the major part of sweat loss originates from the torso and legs, but since both scanners did not produce similar results likely due to differences in accuracy, we recommend using high-resolution scanners to record volume changes in more detail.

Details:

Full paper: 16.045.pdf
Proceedings: 3DBST 2016, 30 Nov.-1 Dec. 2016, Lugano, Switzerland
Pages: 45-53
DOI: 10.15221/16.045

Copyright notice

© Hometrica Consulting - Dr. Nicola D'Apuzzo, Switzerland, www.hometrica.ch.
Reproduction of the proceedings or any parts thereof (excluding short quotations for the use in the preparation of reviews and technical and scientific papers) may be made only after obtaining the specific approval of the publisher. The papers appearing in the proceedings reflect the author's opinions. Their inclusion in these publications does not necessary constitute endorsement by the editor or by the publisher. Authors retain all rights to individual papers.

Proceedings of 3DBODY.TECH International Conferences on 3D Body Scanning & Processing Technologies, © Hometrica Consulting, Switzerland